  • AirSense 11
  • AirCurve 11
Replace every Every 6 months
Overview

This is the heated hose ResMed builds for the AirSense 11 and AirCurve 11. A heating wire runs the tube's length, keeping the air warm all the way to your mask, and it pairs with the HumidAir 11 tub to unlock Climate Control.

The tube itself runs 2 meters long with a 15 mm bore, the same dimensions ResMed has used since the AS10 tube. What sets this one apart is the connector: a flat, gold-pinned fitting built specifically for the Air11 outlet.

Key Features:

  • Manual mode option: Set the tube from 60 to 86 degrees and the humidity across eight levels yourself, though rainout protection is not guaranteed outside Auto.
  • If rainout happens: ResMed's own fix is to raise the tube temperature first, and only lower the humidity if the air then feels too warm.
  • Higher altitude rating: This tube is rated to 9,870 feet, higher than the 8,500 foot rating ResMed gives the AS10 generation tube.
  • Wider storage range: Store it between minus 13 and 158 degrees Fahrenheit, a broader window than the AS10 tube allows.
  • Heat ceiling unchanged: Air inside the tube is still capped at 106 degrees Fahrenheit, the same limit ResMed sets on the AS10 generation.
  • Auto-detects on connect: The screen briefly shows a connection message the moment the cuff seats, with no separate tube setting to hunt for in a menu.

Get this tube if your AirSense 11 or AirCurve 11 hose has gone stiff, cracked, or stopped sealing at either end, whether that is from age or an accidental kink. It replaces exactly what shipped with the machine, connector and all.

How It Works

Why the altitude and storage ranges moved

Both figures come from the tube's own published spec, not the AirSense 11 device's rating, and both moved up from the AS10 generation: a higher altitude ceiling and a wider storage temperature window in both directions.

Neither is likely to matter on an ordinary night at home. They matter more for someone who travels to elevation, or who stores a spare tube somewhere that gets genuinely hot or cold between uses, like a car or an unheated closet.

What the flow numbers mean

ResMed publishes a resistance-to-flow figure for this tube: 0.0077 cm H2O per liter/minute at a 15 L/min flow, rising to 0.0100 at 30 L/min, both measured at a 20 cm H2O set pressure. In plain terms, the tube itself pushes back a little harder as more air moves through it, and that push grows with flow rate.

A separate compliance figure, 0.500 mL per cm H2O at 60 cm H2O, describes how much the tube itself expands under pressure rather than holding perfectly rigid. Both numbers are built into how your machine already compensates for pressure delivered at the mask, not something you need to adjust for.

Setting it up, and what it's made of

The electrical connector end is exclusive to the air outlet at the back of the machine and should never be pushed onto the mask end by mistake. Line the cuff up, push it in firmly, and connect the mask to the free end of the tube.

ResMed lists the tube's construction as flexible plastic with electrical components built in, which is what carries both the airflow and the heating signal in one piece rather than as two separate parts.

What's Included

Here's everything that comes in the box.

  • One ResMed ClimateLineAir 11 heated tube, 2 m long with a 15 mm bore

Everything you need to know about the ResMed ClimateLineAir Heated Tube for AirSense 11 & AirCurve 11

Built for standard therapy, not oxygen

This is the plain ClimateLineAir 11, without any oxygen fitting built in. If supplemental oxygen is part of your prescription, ResMed builds a separate ClimateLineAir 11 Oxy with its own built-in oxygen inlet, a different tube entirely with its own part number.

Not compatible with the AirSense 10

The connector shape changed between generations: flat with exposed gold pins here, against the older tube's round barrel and blue retaining ring. An AirSense 10 or AirCurve 10 needs its own ClimateLineAir tube, not this one.

What worn actually looks like

A ClimateLineAir 11 that has gone stiff, cracked, or stopped sealing at either cuff is doing less than it should, whatever the calendar says. That is usually the tube reaching the end of its working life, not a one-off defect.

ResMed ClimateLineAir 11 heated tube coiled on white, flat gold-pin connector visible at the machine end

Auto holds steady

The tub and this tube together keep the air at a steady 80 degrees and 85 percent humidity, no adjusting needed.

Six month life

ResMed rates this tube for six months of regular use before the material starts to lose its seal and flexibility.

Weekly wash

Wash it weekly in warm water under 131 degrees with a mild dishwashing liquid, skipping the dishwasher entirely.

Needs the tub

Climate Control only switches on once this tube and the Air11 humidifier tub are both attached to the machine together.

Frequently Asked Questions

Will this fit my AirSense 10?

No. The AirSense 10 and AirCurve 10 use a round barrel connector with a blue retaining ring, not this tube's flat, gold-pinned Air11 fitting. Order the ClimateLineAir tube built for the AS10 generation instead.

Is this the Oxy version?

No, this is the plain ClimateLineAir 11. ResMed sells a separate ClimateLineAir 11 Oxy with a built-in oxygen port under its own part number, for anyone whose therapy includes supplemental oxygen.

How should I clean it?

Wash it weekly in warm water, no hotter than 131 degrees Fahrenheit, using a mild household dishwashing liquid. Rinse it well and let it air dry away from direct sunlight or heat. Never a dishwasher or washing machine.

How often does ResMed say to replace it?

Every six months under normal nightly use. Replace it sooner if you see any cracking, discoloration, or tearing, since a damaged tube should be discarded rather than patched.

What happens when I plug it in?

The device briefly shows "ClimateLine connected" on screen the moment the cuff seats. There is no separate tube-type setting to find in the menu, since the machine detects it automatically through the connector's contacts.

Need help?Our experts are here for you.

Since 1986 we have helped people get the right equipment and the help to use it. Call or chat with our team.

  • Industry-leading customer service
  • Live chat & phone support
  • Best deals & helpful tips